Howdy all, I recently got a Milwaukee Road SD-7 in N scale. Came with the Lenz LE06XF decoder. On the box , the label states that the decoder supports rule 17 dimming. Just how do I go about programming the decoder for that? Which CV's is it, and what values do I need to use? Also what is the CV and value to get a Lenz decoder back to factory defaults? Any help would be greatly appriciated. Adios Wyatt
Hi Wyatt, Just did a quick check on http://www.lenz.com/manuals/ and can't find any decoder named LE06XL. There is a decoder called LE062XL, could it be bad spelling? To get Rule 17 on LE062, set bit0=1 in CV51 About factory default, I can't find anything for that decoder. Leif.
CV 51 = 15 (decimal) which sets the following parameters: F0 turns headlight F1 turns rear light F4 dims both. 15 = 0000 1111 in binary hth Michael
There is also a Lenz 063 decoder. As was said above, set CV 51 to 15 To set the decoder to factory default values, set CV 8 =99 Have fun Wyatt... Stay cool and run steam....
Thanx all, works like a charm, I programmed CV52 for the brightness of the dim. Works great!! Thanx for the help.. adios Wyatt