Need help wiring Peco electrofrog crossing

txronharris Mar 12, 2005

  1. txronharris

    txronharris TrainBoard Member

    1,081
    475
    37
    Howdy all. Got all my papermill trackage laid and yep, lost the instructions on wiring my Peco code 55 electrofrog crossing. There are 4 wires (2 on each side) that I'm not sure where to put. Any help, as always, would be appreciated :D !
     
  2. Flash Blackman

    Flash Blackman TrainBoard Member

    13,326
    503
    149
    txron

    I wired mine so that when one track is hot, the other is dead. I just use a dpdt switch to make the change, depending on which track is in use. I use gaps aon all four approach tracks so there is no question of polarity.
     
  3. txronharris

    txronharris TrainBoard Member

    1,081
    475
    37
    Thanks Flash. I knew someone here could help me out!
     
  4. Paul Downs

    Paul Downs TrainBoard Supporter

    193
    0
    23
    I have 3 on my passenger station module, and because I can't "read" them to save my life, I added two Peco switch machines (PL-10 or PL-10 E) along with the Peco accessory switch (PL-13). I use the "probe-and-stud" method to throw the turnouts, but any momentary-on switch could also be used.

    The extra wires are for the frogs, to make them electrically "live" so that dead spots are reduced.

    Flash is right about isolating them. I did the same.
     