Simple (i hope) reverse loop question.. newbie

hepkat63 Nov 9, 2010

  1. hepkat63

    hepkat63 TrainBoard Member

    11
    0
    8
    Hi All,
    I was having a problem with my layout (see picture), which your forum members very quickly pointed out to me that the blue section is a reverse loop and the way I had it hooked up (without any reverse switch) is why my layout kept shorting out (told you i was a newbie...).
    Ok, that identified (and disconnected), all works well. So, I need to know how to wire it up so it WILL work now !
    I have found: The Digitrax AR1 (Digitrax.com: Digitrax AR1 Auto Reversing Controller ) and was wondering if:
    1. this is the correct device to use
    2. how many I will need
    3. although I have downloaded the .pdf from their website, I am a little confused on if I need one, or two and how to wire it applicable to the blue section on my layout

    Would anyone be so kind as to throw some light on this please?
    [​IMG]
     
  2. maxairedale

    maxairedale TrainBoard Member

    1,739
    133
    34
    Yes VERY simple

    Yes VERY simple[​IMG]

    To answer your questions

    1. Yes
    2. One
    3. Just one for each reversing loop, the AR1 goes between the main DCC track power and the reversing section, providing the correct polarity for the reversing section. Both ends of the reversing section HAVE to be insulated (Double Gap) from the other tracks. The AR1's are very simple to install and adjust if needed. Two wires in (Track A & B, From the Main Line) and two wires out (Out To Reversing Section).

    [​IMG]

    [​IMG]

    I use the AR1 on my layout without any trouble.

    Gary
     

    Attached Files:

  3. woodone

    woodone TrainBoard Member

    959
    51
    24
    I am asking what system you are using? NCE's Power Cab will not work with a AR-1.
    So if that is the system you have this will not work.
     
  4. hepkat63

    hepkat63 TrainBoard Member

    11
    0
    8
    thanks Guys - much appreciated (i am using kato unitrack).
     
  5. virgule

    virgule TrainBoard Member

    225
    6
    11
    eh? I have NCE Power Cab and Digitrax AR-1. They work just fine. Only had to adjust the trip screw a little as instructed.
     

Share This Page